Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun Fire™X4150 ServerInstallation GuidePart
x Sun Fire X4150 Server Installation Guide • May 2009Sun Welcomes Your CommentsSun is interested in improving its documentation and welcomes your comm
1CHAPTER1Before You BeginThis chapter describes how to set up the Sun Fire X4150 server hardware. It includesthe following topics: “Tools and Equipme
2 Sun Fire X4150 Server Installation Guide • May 2009FIGURE 1-1 Sun Fire X4150 Server Installation Process (Part 1)“Connecting the Cables” on page 28S
Chapter 1 Before You Begin 3FIGURE 1-2 Sun Fire X4150 Server Installation Process (Part 2)Sun StorageTek: Sun StorageTek RAID ManagerUser's Guide
4 Sun Fire X4150 Server Installation Guide • May 2009Unpacking the BoxesUnpack all server components from the packing cartons.Package Contents Invento
Chapter 1 Before You Begin 5Antistatic PrecautionsElectronic equipment is susceptible to damage by static electricity. Use a groundedantistatic wrists
6 Sun Fire X4150 Server Installation Guide • May 2009Sun Fire X4150 Server DescriptionThis section shows the front and back of the Sun Fire X4150 serv
Chapter 1 Before You Begin 7Back PanelFIGURE 1-4 shows the back panel. TABLE 1-2 describes the back panel features.FIGURE 1-4 Back PanelTABLE 1-2 Back
8 Sun Fire X4150 Server Installation Guide • May 2009
9CHAPTER2Installing the Sun Fire X4150 ServerInto a Rack with Slide-RailsThis chapter describes how to place the Sun Fire X4150 server into a rack usi
PleaseRecycleCopyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.THIS PRODUCT CONT
10 Sun Fire X4150 Server Installation Guide • May 20091. “Checking Compatibility” on page 102. “Disassembling Slide-Rails” on page 113. “Installing th
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 11Caution – Always load equipment into a rack from the bottom up so that i
12 Sun Fire X4150 Server Installation Guide • May 2009Disassembling Bolt-On Slide-RailsTo remove the mounting-brackets from the bolt-on slide-rail ass
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 13Installing the Mounting-Brackets Onto the ServerTo install the mounting-
14 Sun Fire X4150 Server Installation Guide • May 2009Attaching the Slide-Rail Assemblies to the RackDo one of the following procedures to attach the
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 15FIGURE 2-3 Slide-Rail Assembly Mounting to Rack Post3. Repeat Step 1 and
16 Sun Fire X4150 Server Installation Guide • May 2009FIGURE 2-4 Setting the Rail Width5. Tighten the screws on the brackets.6. Remove the spacer and
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 178. If available, extend the anti-tip foot at the bottom of the rack. (Se
18 Sun Fire X4150 Server Installation Guide • May 2009Caution – Always load equipment into a rack from the bottom up so that it will notbecome top-hea
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 194. Simultaneously push and hold the slide-rail release buttons on each m
iiiContentsPreface vii1. Before You Begin 1Tools and Equipment Needed 1Installation Process Flowchart 1Unpacking the Boxes 4Package Contents Inventory
20 Sun Fire X4150 Server Installation Guide • May 20093. Remove tape to separate parts.The CMA rail extension might be taped to the CMA arm.4. Attach
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 215. Verify that the CMA rail extension engages the slide-rail, as shown i
22 Sun Fire X4150 Server Installation Guide • May 20096. Insert the CMA’s mounting-bracket connector into the right slide-rail until theconnector lock
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 23FIGURE 2-11 Inserting CMA Slide-Rail Connector Into the Back of the Righ
24 Sun Fire X4150 Server Installation Guide • May 20098. Insert the left CMA slide-rail connector into the rail extension on the left slide-rail assem
Chapter 2 Installing the Sun Fire X4150 Server Into a Rack with Slide-Rails 2510. Attach the hook and loop straps to the CMA, and press them into plac
26 Sun Fire X4150 Server Installation Guide • May 2009Verifying Operation of the Slide-railsand CMAUse this procedure to ensure that the slide-rails a
27CHAPTER3Setting Up the Sun Fire X4150 ServerThis chapter describes how to connect cables and power up the Sun Fire X4150server for the first time. I
28 Sun Fire X4150 Server Installation Guide • May 2009Connecting the CablesConnect the power and data cables from the server back panel to your system
Chapter 3 Setting Up the Sun Fire X4150 Server 29Cabling the ServerConnect the server power cables, and external cables in the following order:1. Conn
iv Sun Fire X4150 Server Installation Guide • May 2009Installing the Mounting-Brackets Onto the Server 13Attaching the Slide-Rail Assemblies to the Ra
30 Sun Fire X4150 Server Installation Guide • May 20097. Connect to the Lights Out Manager (LOM) SP. See the next section.Caution – Do not operate the
Chapter 3 Setting Up the Sun Fire X4150 Server 31TABLE 3-2 Embedded LOM Service Processor ComponentsItem Port Function1ELOM hardwareELOM includes the
32 Sun Fire X4150 Server Installation Guide • May 2009Note – The factory has configured the service processor hardware and firmware onyour server with
Chapter 3 Setting Up the Sun Fire X4150 Server 33 Manages the inventory of hot-pluggable system componentsRefer to the Sun Integrated Lights Out Mana
34 Sun Fire X4150 Server Installation Guide • May 2009About Service Processor InterfacesAfter you configure the IP address to comply with your network
Chapter 3 Setting Up the Sun Fire X4150 Server 352. When the Sun Microsystems splash screen or text prompt appears during thePower On Self Test (POST)
36 Sun Fire X4150 Server Installation Guide • May 2009Note – If you connect to the serial port on the LOM before it has been powered onor during its p
Chapter 3 Setting Up the Sun Fire X4150 Server 37Modifying the Service Processor IPAddressThe following examples show how to change the current IP add
38 Sun Fire X4150 Server Installation Guide • May 2009Method 2: Using the Serial ConnectionExample 1To change the SP DHCP IP address to a static IP ad
Chapter 3 Setting Up the Sun Fire X4150 Server 3910. To assign a static IP ADDRESS, type the following commands in exact order:ELOM:set /SP/network IP
Contents vInstallation Worksheet 47Configuring the Solaris OS 49Redirect the Console Output to the Video Port (Optional) 50Using the GRUB Menu 50Confi
40 Sun Fire X4150 Server Installation Guide • May 20097. Type the following command to change a static address to a DHCP address:ELOM:set /SP/network
Chapter 3 Setting Up the Sun Fire X4150 Server 419. Record your settings.10. Log out.11. If the IP address changes, you must reconnect using the newly
42 Sun Fire X4150 Server Installation Guide • May 2009f. Press Enter on the terminal device to establish a connection between theterminal device and t
Chapter 3 Setting Up the Sun Fire X4150 Server 43Installing the Intel PROSET TeamingUtilityThe Intel PROSET teaming utility is optional for Windows sy
44 Sun Fire X4150 Server Installation Guide • May 2009
45CHAPTER4Configuring the PreinstalledSolaris 10 Operating SystemThis chapter describes how to configure the Solaris™ 10 operating system (OS) thatmig
46 Sun Fire X4150 Server Installation Guide • May 2009 Deliver the preinstalled Solaris 10 image using a directly connected monitor andkeyboard.About
Chapter 4 Configuring the Preinstalled Solaris 10 Operating System 47Installation WorksheetFill in TABLE 4-1 with information you need to configure th
48 Sun Fire X4150 Server Installation Guide • May 2009Name service: ifthe system usesa name service,provide thefollowinginformation.Name service Which
Chapter 4 Configuring the Preinstalled Solaris 10 Operating System 49Configuring the Solaris OSTo configure the preinstalled Solaris OS:1. Log in to t
vi Sun Fire X4150 Server Installation Guide • May 2009Power On the Main Power 65Power Off from Main Power Mode 66Setup Troubleshooting 67Contacting Su
50 Sun Fire X4150 Server Installation Guide • May 2009Refer to the Sun Integrated Lights Out Manager Users Guide for detailedinformation.3. Follow the
Chapter 4 Configuring the Preinstalled Solaris 10 Operating System 511. Open the /boot/grub/menu.lst file in a text editor.2. Modify the following lin
52 Sun Fire X4150 Server Installation Guide • May 2009RAID Drive OptionsTABLE 4-3 shows the RAID drive options:TABLE 4-3 RAID Drive OptionsSAS Card Dr
Chapter 4 Configuring the Preinstalled Solaris 10 Operating System 53Mirroring the Preinstalled Solaris OSwith LSI RAIDThe Solaris OS supports hardwar
54 Sun Fire X4150 Server Installation Guide • May 2009Creating a RAID Set to Incorporate a PreinstalledOS Using the Sun StorageTek CardThe Sun Storage
Chapter 4 Configuring the Preinstalled Solaris 10 Operating System 55Tip – HDD0 (OS) should be Enclosure 0 Logical Volume 1.11. To mirror the OS, righ
56 Sun Fire X4150 Server Installation Guide • May 2009Downloading Solaris 10 OS SoftwareIf you need to install the Solaris 10 11/06 OS or reinstall th
57CHAPTER5Configuring the PreinstalledWindows Server 2003 R2Operating SystemThis chapter describes how to configure the Preinstalled Windows Server 20
58 Sun Fire X4150 Server Installation Guide • May 2009Delivery MethodsBy default, video output for the Windows preinstall is directed to the VGA monit
Chapter 5 Configuring the Preinstalled Windows Server 2003 R2 Operating System 592. The EMS Connection Detected dialog box appears. Click OK to contin
viiPrefaceThe Sun Fire X4150 Server Installation Guide provides detailed information about howto install the Sun Fire X4150™ server hardware and softw
60 Sun Fire X4150 Server Installation Guide • May 200913. Set the Date, Time, and Time Zone settings for your locale. Click Next.The network software
Chapter 5 Configuring the Preinstalled Windows Server 2003 R2 Operating System 61Note – Configuring the Sun Fire X4150 server RAID is optional, by def
62 Sun Fire X4150 Server Installation Guide • May 2009Mirroring the Preinstalled Windows Server 2003R2 OS with LSI RAIDThe Windows Server 2003 R2 OS s
Chapter 5 Configuring the Preinstalled Windows Server 2003 R2 Operating System 63Creating a RAID Set to Incorporate a PreinstalledOS Using the Sun Sto
64 Sun Fire X4150 Server Installation Guide • May 200914. One more confirmation screen appears. Confirm the mirroring.The OS begins to mirror. Mirrori
65CHAPTER6If You Need HelpThis chapter describes troubleshooting information and how to apply and removeAC power to the Sun Fire X4150 server. Support
66 Sun Fire X4150 Server Installation Guide • May 2009FIGURE 6-1 Front Panel Power/OK LEDNote – The first time the server powers on, the power on self
Chapter 6 If You Need Help 67Setup TroubleshootingThis section contains information to help you troubleshoot minor server problems.If you experience p
68 Sun Fire X4150 Server Installation Guide • May 2009Note – For additional troubleshooting information, see the Sun Fire X4150 ServerService Manual.C
Chapter 6 If You Need Help 69System serial numberPeripherals attached to the systemEmail address and phone number for you and asecondary contactStreet
viii Sun Fire X4150 Server Installation Guide • May 2009Typographic ConventionsSun OnlineThe following table shows where to find Sun documents online:
70 Sun Fire X4150 Server Installation Guide • May 2009Lists international telephone numbersfor SunService support.http://www.sun.com/service/contactin
71IndexAAccess the BIOS, 34accessory kit, 4Bback panel, 7back panel connectors, 28Before You Begin, 1bolt-on slide-rail assemblies, 12, 14Ccable manag
72 Sun Fire X4150 Server Installation Guide • May 2009Ooptional components, 4Ppassword, 49power cables, 29power off, 65power on, 65Preinstalled Window
Preface ixSun Fire X4150 Server DocumentationTo view the latest Sun Fire X4150 server documentation online, go tohttp://docs.sun.com, and then navigat