64 Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide June 2000
Parameters That Report the Link Partner
Capabilities
TABLE B-8 describes the read-only link partner capabilities.
If the link partner is not capable of autonegotiation (when lp_autoneg_cap is 0)
the information described in
TABLE B-8 is not relevant and the parameter value
equals 0.
If the link partner is capable of autonegotiation (when lp_autoneg_cap is 1), the
speed and mode information are displayed when you use autonegotiation and get
the link partner capabilities.
TABLE B-8 Read-Only Link Partner Capabilities
Parameter Values
lp_autoneg_cap 0 = No autonegotiation
1 = Autonegotiation
lp_100fdx_cap 0 = No 100 Mbit/sec full-duplex transmission
1 = 100 Mbit/sec full-duplex
lp_100hdx_cap 0 = No 100 Mbit/sec half-duplex transmission
1 = 100 Mbit/sec half-duplex
lp_10fdx_cap 0 = No 10 Mbit/sec full-duplex transmission
1 = 10 Mbit/sec full-duplex
lp_10hdx_cap 0 = No 10 Mbit/sec half-duplex transmission
1 = 10 Mbit/sec half-duplex