Chapter 3 Sun StorEdge A3500/A3500FC Configurations 3-9
3.1.4 3x15 Configuration
The 3x15 configuration includes three controller modules with a total of fifteen
StorEdge D1000 disk arrays combined in a 2x7 cabinet or a 1x8 cabinet.
3.1.4.1 Option Switch
All disk arrays are on a single bus and should be set as described in Section 3.1.2.1
“Option Switch” on page 3-5.
3.1.4.2 Module ID Switch
Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to
TABLE 3-4 and TABLE 3-5.
TABLE 3-4 3x15 Module ID Switch Settings in the 2x7 Cabinet
Disk Array Number Module ID Setting
7 (Top) 5
64
53
42
31
21
1 (Bottom) 2
TABLE 3-5 3x15 Module ID Switch Settings in the 1x8 Cabinet
Disk Array Number Module ID Setting
8 (Top) 5
74
63
52
41
35
24
1 (Bottom) 3