Sun Microsystems PCI-X Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery Sun Microsystems PCI-X. Sun Microsystems PCI-X User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorageTek
Enterprise PCI-X
4 Gb FC Single and Dual Port
Emulex Host Bus Adapters
Installation and Basic Interoperability Guide
Part No. 819-5532-12
January 2007, Revision A
Zobrazit stránku 0
1 2 3 4 5 6 ... 67 68

Shrnutí obsahu

Strany 1 - Emulex Host Bus Adapters

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun StorageTek™Enterprise PCI-X4 Gb FC Sing

Strany 2

x Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Strany 3 - Contents

xiPrefaceThis manual describes how to install, configure, and test the Sun StorageTek™Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emu

Strany 4

xii Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Using UNIX CommandsThis d

Strany 5 - Contents v

Preface xiiiTypographic ConventionsRelated DocumentationThe following documents are available at:http://www.sun.com/products-n-solutions/hardware/docs

Strany 6

xiv Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Documentation, Support, a

Strany 7

1CHAPTER1Product OverviewThis chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 GbFC Single and Dual Port Emulex HBAs (hencef

Strany 8

2 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Single and Dual Port HBA Fe

Strany 9

Chapter 1 Product Overview 3Minimum System HardwareRequirementsYour system must have an available PCI or PCI-X 64-bit slot to support these singleand

Strany 10

4 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Supported Operating Systems

Strany 11 - Dual SG-XPCI2FC-EM4-Z

5CHAPTER2Supported System ConfigurationsThis chapter describes the operating systems, host platforms, storage, andinfrastructure configurations that s

Strany 12 - Shell Prompts

PleaseRecycleCopyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, I

Strany 13 - Typographic Conventions

6 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Basic InteroperabilityThis

Strany 14 - Sun Welcomes Your Comments

Chapter 2 Supported System Configurations 7Storage System SupportThe single and dual port HBAs support the storage systems are listed below. Sun Stor

Strany 15 - Product Overview

8 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Solaris 8, 9, and 10 Operat

Strany 16 - Feature Description

Chapter 2 Supported System Configurations 9Red Hat Enterprise Linux and SuSELinux Enterprise Server OperatingSystem RequirementsThis section contains

Strany 17 - Requirements

10 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Windows 2000 and Windows S

Strany 18 - Supported Operating Systems

Chapter 2 Supported System Configurations 11 CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transportfailure for a’timeout’ reas

Strany 19

12 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Strany 20 - Basic Interoperability

13CHAPTER3Hardware InstallationThis chapter provides instructions for installing the Sun StorageTek Enterprise PCI-X4 Gb FC Single and Dual Port Emule

Strany 21 - Fibre Channel Switch Support

14 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Verify the Packaging

Strany 22

Chapter 3 Hardware Installation 15FIGURE 3-1 Removing the Bracket Screwsb. Remove the bracket and store it for future use.c. Align the new mounting br

Strany 23 - System Requirements

iiiContentsPreface xi1. Product Overview 1Single and Dual Port HBA Features 2Minimum System Hardware Requirements 3Supported Operating Systems 42. Sup

Strany 24 - Known Issues and Bugs

16 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007FIGURE 3-2 Installing the

Strany 25

Chapter 3 Hardware Installation 17Follow these steps when attaching the optical cable:1. Connect the fiber-optic cable to an LC connector on the dual

Strany 26

18 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Apply Power1. Verify

Strany 27 - Hardware Installation

Chapter 3 Hardware Installation 19▼ To Verify Proper Installation in SPARCPlatforms1. Enter the show-devs command at the ok prompt to list the install

Strany 28 - To Install the HBA Hardware

20 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 20072. To positively identify

Strany 29 - Removing the Bracket Screws

Chapter 3 Hardware Installation 21▼ To Verify the Attached Storage● If online storage is connected to the HBA installed in a SPARC system, use theappl

Strany 30 - To Attach the Optical Cable

22 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Verify Proper Install

Strany 31 - Optical Cable Specifications

23CHAPTER4Software InstallationAfter you have completed the hardware installation and powered on the computer,follow the instructions listed for your

Strany 32 - To Apply Power

24 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Strany 33 - Platforms

Chapter 4 Software Installation 25The packages and patches are available either bundled as a script posted in the SunDownload Center (SDLC), or as ind

Strany 34 - TABLE 3-3

iv Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-3. Hardware Installation 13▼ To Veri

Strany 35 - TABLE 3-4

26 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Do A Manual Installat

Strany 36 - Service Contact Information

Chapter 4 Software Installation 271. Go to http://sunsolve.sun.com.The SunSolve Online license agreement page displays.2. Accept the License Agreement

Strany 37 - Software Installation

28 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Downloading HBA Driver Pac

Strany 38 - Operating Systems

Chapter 4 Software Installation 29▼ To Download the PatchesPerform the following steps to download the Solaris 10 patches.1. Go to http://sunsolve.sun

Strany 39

30 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Strany 40 - To Do A Manual Installation

Chapter 4 Software Installation 31Red Hat and SuSE OS Diagnostic SupportDiagnostic support is provided by the Emulex lputil and HBAnyware utilities.Th

Strany 41 - Sun Solaris 8 and 9 Patches

32 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Strany 42 - To Download the Packages

Chapter 4 Software Installation 33▼ To Install the Diagnostic and ManagementUtilitiesDiagnostic support is provided by the Emulex lputil and HBAnyware

Strany 43 - Diagnostic Support

34 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Strany 44

35APPENDIXADeclaration of Conformity,Regulatory Compliance, and SafetyStatementsThis appendix contains the following information that applies to the S

Strany 45 - Creating a Linux Boot Disk

Contents v▼ To Create a Windows Boot Disk 33Service Contact Information 33A. Declaration of Conformity, Regulatory Compliance, and Safety Statements 3

Strany 46

36 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Strany 47

37Declaration of ConformityEMCUSA—FCC Class AThis equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditio

Strany 48

38 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007/S/ /S/Dennis P. Symanski

Strany 49 - Statements

39Regulatory Compliance StatementsYour Sun product is marked to indicate its compliance class:• Federal Communications Commission (FCC) — USA• Industr

Strany 50

40 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007ICES-003 Class A Notice -

Strany 51

Regulatory Compliance Statements 41BSMI Class A NoticeThe following statement is applicable to products shipped to Taiwan and marked as Class A on the

Strany 52

42 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Strany 53 - FCC Class A Parts

43Safety Agency ComplianceStatementRead this section before beginning any procedure. Thefollowing text provides safety precautions to follow wheninsta

Strany 54

44 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Power Cord ConnectionCauti

Strany 55 - GOST-R Certification Mark

Safety Agency Compliance Statement 45Rack System WarningThe following warnings apply to Racks and Rack Mountedsystems.Caution – For safety, equipment

Strany 56

vi Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Strany 57 - Statement

46 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007SymbolesVous trouverez ci-

Strany 58 - System Unit Cover

Safety Agency Compliance Statement 47Attention – Tous les cordons d'alimentationne présentent pas les mêmes caractéristiquesélectriques. Les cord

Strany 59 - Mesures de sécurité

48 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Attention – Afin d'év

Strany 60

Safety Agency Compliance Statement 49Je nach Netzschaltertyp an Ihrem Gerät kann eines derfolgenden Symbole verwendet werden:Ein – Versorgt das System

Strany 61 - Couvercle de l'unité

50 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Die folgende Warnung gilt

Strany 62 - Vorschriften

Safety Agency Compliance Statement 51Hinweis zur Laser-KonformitätSun-Produkte, die die Laser-Technologie verwenden,entsprechen den Laser-Anforderunge

Strany 63 - Anschluss des Netzkabels

52 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Nivel de ruidoDeclared noi

Strany 64 - Gehäuseabdeckung

Safety Agency Compliance Statement 53Cubierta de la unidad del sistemaDebe extraer la cubierta de la unidad del sistemainformático Sun para instalar t

Strany 65 - Normativas de seguridad

54 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007DanmarkAdvarsel! – Litiumb

Strany 66 - Nivel de ruido

viiFiguresFIGURE 3-1 Removing the Bracket Screws 15FIGURE 3-2 Installing the Single and Dual Port HBAs 16FIGURE 3-3 Attaching the Optical Cable 17

Strany 67 - Laser Klasse 1

viii Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Strany 68

ixTablesTABLE 1-1 Single and Dual Port HBA Features 2TABLE 2-1 Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windo

Komentáře k této Příručce

Žádné komentáře