40 Netra 1290 Server Installation Guide May 2006
8. Booting the Solaris Operating System.
9. Installing the Lights Out Management packages from the Sun Microsystems
software download center.
Setting Up the Hardware
To Install and Cable the Hardware
1. Connect a terminal to the system controller board serial port (FIGURE 1-26).
2. Set up the terminal to use the same baud rate as the SC serial port.
The serial port settings of the System Controller board are:
9600 baud
8 data bits
No parity
1 stop bit
On/Standby Switch
The On/Standby switch is a rocker switch with two positions, On and Standby.
FIGURE 2-1 illustrates the switch and its location.
FIGURE 2-1 Netra 1290 Server On/Standby Switch
On/Standby
switch