Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorageTek
8 Gb FC PCI-
Express HBA, Emulex Installation
Guide
For HBA Models SG-XPCIE1FC-EM8-Z and
SG-XPCIE2FC-EM8-Z
Part No. 820-5465-12
December 2008, Revision A
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - 8 Gb FC PCI

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun StorageTek™8 Gb FC PCI-Express HBA, Emu

Strany 2

x Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008

Strany 3 - Contents

xiSafety Agency ComplianceStatementsRead this section before beginning any procedure. Thefollowing text provides safety precautions to follow wheninst

Strany 4

xii Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008products). To reduce the risk of electric shock,do not plug Sun p

Strany 5 - Declaration of Conformity

Safety Agency Compliance Statements xiiiSystem Unit CoverYou must remove the cover of your Sun computer systemunit to add cards, memory, or internal s

Strany 6

xiv Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008SymbolesVous trouverez ci-dessous la signification des différents

Strany 7 - FCC Class A Notice

Safety Agency Compliance Statements xvutilisés avec des ordinateurs. N'utilisez jamaisde cordon d'alimentation à usage domestiqueavec les pr

Strany 8 - GOST-R Certification Mark

xvi Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Avis de conformité des appareils laserLes produits Sun qui font a

Strany 9

Safety Agency Compliance Statements xviitung dieser Richtlinien kann Überhitzungverursachen und die Zuverlässigkeit IhresSun-Geräts beeinträchtigen.La

Strany 10

xviii Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Achtung – Nehmen Sie Sun-Geräte nichtohne Abdeckung in Betrieb.

Strany 11 - Statements

Safety Agency Compliance Statements xixPrecaución – Superficie caliente. Evite todocontacto. Las superficies están calientes ypueden causar lesiones p

Strany 12 - Battery Warning

Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, Inc. has intel

Strany 13 - CD and DVD Devices

xx Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008de tierra situada cerca del sistema y de fácilacceso. No conecte e

Strany 14

Safety Agency Compliance Statements xxiDispositivos de CD y DVDLa siguiente medida se aplica a los dispositivos de CD yDVD, así como a otros dispositi

Strany 15 - Couvercle de l'unité

xxii Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008

Strany 16 - Vorschriften

xxiiiPrefaceThis installation guide describes how to install and remove the single and dual portSun StorageTek™ 8 Gigabit (Gb) Fibre Channel (FC) PCI-

Strany 17 - Gehäuseabdeckung

xxiv Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Chapter 4 contains known issues with the HBA.Using UNIX Commands

Strany 18 - Normativas de seguridad

Preface xxvTypographic ConventionsNote – Characters display differently depending on browser settings. If charactersdo not display correctly, change t

Strany 19

xxvi Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Third-Party Web SitesSun is not responsible for the availability

Strany 20 - Laser Klasse 1

1CHAPTER1HBA OverviewThis chapter provides a basic overview of the single and dual port Sun StorageTek™8 Gb Fibre Channel (FC) PCI-Express host bus ad

Strany 21

2 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008HBA Features and SpecificationsThe Sun StorageTek 8 Gb FC PCI-Expre

Strany 22

Chapter 1 HBA Overview 3Operating System and TechnologyRequirementsThe HBA requires the OS and technology levels listed in TABLE 1-2.Maximum FC cable

Strany 23 - How This Book Is Organized

iiiContentsDeclaration of Conformity vRegulatory Compliance Statements viiSafety Agency Compliance Statements xiPreface xxiii1. HBA Overview 1Kit Cont

Strany 24 - Shell Prompts

4 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008System InteroperabilityThis section provides information about sele

Strany 25 - Typographic Conventions

Chapter 1 HBA Overview 5The host system must have at least one PCI-Express 8-lane slot to support the HBA.Storage SupportThis section lists the arrays

Strany 26 - Sun Welcomes Your Comments

6 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Array SupportThe HBA is supported by the following arrays: Sun Sto

Strany 27 - HBA Overview

Chapter 1 HBA Overview 7 Brocade 200E switch Brocade 300 switch Brocade SW4100 switch Brocade SW4900 switch Brocade SW5000 switch Brocade SW5100

Strany 28

8 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Altitude 3200m 12,200mVibration 0.20G in all axes swept for 5-500 H

Strany 29 - Requirements

9CHAPTER2Hardware Installation and RemovalThis chapter describes the tasks required to install and remove the HBA. Refer toyour system installation or

Strany 30 - System Interoperability

10 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 Hold the HBA by the edge of the PCB, not by the connectors. Pla

Strany 31 - Storage Support

Chapter 2 Hardware Installation and Removal 11a. Remove the transceiver from its cage assembly (see FIGURE 2-2) by pulling thebail (handle) out and do

Strany 32 - Switch Support

12 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008b. Observing ESD precautions, store the transceiver in an ESD-safe

Strany 33 - Environmental Requirements

Chapter 2 Hardware Installation and Removal 139. Replace the computer case and tighten the case screws.The HBA is now installed in the computer and is

Strany 34 - Altitude 3200m 12,200m

iv Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Observing ESD and Handling Precautions 9Installing the Hardware 10

Strany 35 - Precautions

14 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008FIGURE 2-4 Attaching the Optical Cable2. Connect the other end of

Strany 36 - Installing the Hardware

Chapter 2 Hardware Installation and Removal 15FIGURE 2-5 LEDs4. Observe the light-emitting diode (LED) status for the power-on self test (POST)results

Strany 37 - Optical Transceiver

16 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008Testing the InstallationThis section contains the following topics

Strany 38

Chapter 2 Hardware Installation and Removal 17(continued)/pci@7c0/pci@0/pci@9/SUNW,emlxs@0,1/fp@0,0/disk/pci@7c0/pci@0/pci@9/SUNW,emlxs@0/fp@0,0/pci@7

Strany 39 - Optical Cable Specifications

18 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 20082. To positively identify the port as a Sun StorageTek 8 Gb FC por

Strany 40 - ▼ (LED) Status

Chapter 2 Hardware Installation and Removal 19In this example, the .properties command output displays the properties ofthe two ports in a dual port H

Strany 41 - LED Status

20 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008▼ To Verify Attached Storage (for the Solaris OS)● If online stora

Strany 42 - Testing the Installation

Chapter 2 Hardware Installation and Removal 21Note – You might need to use the reset-all command before using the applyshow-children command.In the ex

Strany 43

22 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008(continued)Device PortID 20600 WWPN 200600a0b8220345 LUN 0

Strany 44 - .properties command

Chapter 2 Hardware Installation and Removal 23Replacing the SFP+ Unit on the HBAThe Small Form Factor Pluggable (SFP+) optics unit on this card is con

Strany 45

vDeclaration of ConformityEMCUSA—FCC Class AThis equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two condition

Strany 46

24 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008

Strany 47

25CHAPTER3HBA Software InstallationAfter you have completed the hardware installation and powered on the system,follow the instructions in this chapte

Strany 48

26 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 Connectivity verification Firmware version and checksum test S

Strany 49 - Removing the Hardware

Chapter 3 HBA Software Installation 277. Install the driver for Linux as described in the Emulex Driver and Utilities forLinux User Manual.8. Install

Strany 50

28 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008▼ To Install the Software For the Windows Server2003 or Windows Se

Strany 51 - HBA Software Installation

29CHAPTER4Known IssuesThis chapter contains any known issues with the HBA.Reboot Fails on the SPARC EnterpriseM8000 System (6728135)On the SPARC Enter

Strany 52 - SUSE Linux OSes

30 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008

Strany 53 - Technology

vi Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008./S/ /S/Dennis P. Symanski DATE Donald Cameron DATEWorldwide Compl

Strany 54

viiRegulatory Compliance StatementsYour Sun product is marked to indicate its compliance class:• Federal Communications Commission (FCC) — USA• Indust

Strany 55 - Known Issues

viii Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008BSMI Class A NoticeThe following statement is applicable to prod

Strany 56

Regulatory Compliance Statements ix

Příbuzné modely SG-XPCIE2FC-EM8-Z

Komentáře k této Příručce

Žádné komentáře