Chapter 9 Troubleshooting Virtualization Engine Devices 109
Sun Proprietary/Confidential: Internal Use Only
Error Log Analysis Commands
To Display the Log Files and Retrieve SRNs
Type
Errors that need action are returned in the following format:
A description of the errors follows.
# /opt/svengine/sduc/sreadlog
TimeStamp:
nnn
:T
xxxxx.uuuuuuuu
SRN=
mmmmm
TimeStamp:
nnn
:T
xxxxx.uuuuuuuu
SRN=
mmmmm
TimeStamp:nnn:Txxxxx.uuuuuuuu SRN=mmmmm
Item Description
TimeStamp The time and date when the error occurred
nnn The name of the virtualization engine pair (v1 or v2)
Txxxxx
1
The LUN where the error occurred
uuuuuuuu The unique ID of the drive or the virtualization engine router
SRN=mmmmm The SRN defined in numerical order. Refer to “Virtualization Engine
References” on page 155 for the SRN codes.
1 Txxxxx can represent a physical or a logical LUN.