Chapter 2 General Troubleshooting Procedures 19
Sun Proprietary/Confidential: Internal Use Only
Note To confirm that a failover is occurring, open a Telnet session to the Sun
StorEdge T3+ array and check the output of port listmap.
Another, but slower, method is to run the runsecfg script and verify the
virtualization engine maps by polling them against a live system.
Caution During the failover, small computer systems interface (SCSI) errors will
occur on the data host and a brief suspension of I/O will occur.
To Put the c2 Path Back into Production
1. Type:
2. Verify that I/O has resumed on all paths.
# cfgadm -c configure c2::2b000060220041f4