24 Sun StorEdge 3000 Family Best Practices Manual October 2003
High-Performance SAN Tips and Techniques
In the high-performance SAN configuration, the switches communicate with the
Sun StorEdge 3510 FC array host ports using a fabric loop (FL_port) mode. This
enables every Fibre Channel host connection within the Sun StorEdge 3510 FC
array to send and receive data from servers, resulting in optimum performance.
Use of fabric loop (FL_port) connections between a Sun StorEdge 3510 FC array
and fabric switches enables up to 1024 total LUNs to be presented to servers.
However, using such a large number of LUNs adversely affects performance.
High-Performance SAN Setup Details
The following example applies to a dual-controller array in a loop configuration.
Host Adapters per
server
Dual-port 2-Gbit FC Dual-port 2-Gbit FC Dual-port 2-Gbit FC
Traffic Manager Required Required Required
Storage Switches Two 8-port 2-Gbit
FC fabric switches
Two 16-port 2-Gbit
FC fabric switches
Two 32-port 2-Gbit
FC fabric switches
TABLE 7 Configuration Overview for High-Performance SAN (Continued)
Small Configuration Medium Configuration Large Configuration